ETQ DG6LE Owner's Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 34
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
EASTERN TOOLS & EQUIPMENT INC Tele: (888)908-6200 Web Site: easterntools.com
8
2-3 Checking the operation of the diesel
engine
2-3 Checking the operation of the diesel
engine
Fuel switch
2-3.1 Low-pressure alarm system. 2-3.1 Low-pressure alarm system.
ETQ diesel engines have a low-pressure sensor
system where if the oil pressure drops too low,
the sensor will shut the engine off. The purpose
of having this system is to ensure that the engine
does not seize up. If there is not enough oil in
the engine, the temperature of the oil will be
raised too high. On the contrary, if there is too
much oil in the engine, the engine oil can slow the
engine down considerably.
ETQ diesel engines have a low-pressure sensor
system where if the oil pressure drops too low,
the sensor will shut the engine off. The purpose
of having this system is to ensure that the engine
does not seize up. If there is not enough oil in
the engine, the temperature of the oil will be
raised too high. On the contrary, if there is too
much oil in the engine, the engine oil can slow the
engine down considerably.
2-3.2 Engine break in 2-3.2 Engine break in
When you purchase a brand new engine, the
engine must be properly broken in. The break in
period is about 20 hours.
When you purchase a brand new engine, the
engine must be properly broken in. The break in
period is about 20 hours.
(1) Avoid overloading the engine when brand
new.
(1) Avoid overloading the engine when brand
new.
(2) Change the engine oil according to
specifications. An oil change for a brand new
engine is about 20 hours or every month, an
older engine, the oil change is about 100
hours or three months.
(2) Change the engine oil according to
specifications. An oil change for a brand new
engine is about 20 hours or every month, an
older engine, the oil change is about 100
hours or three months.
2-4 Starting the generator set 2-4 Starting the generator set
2-4.1 Manual starting. 2-4.1 Manual starting.
Start the engine in accordance with procedures
below:
Start the engine in accordance with procedures
below:
(1) Put the fuel switch in the “On” position. (1) Put the fuel switch in the “On” position.
(2) Turn the speed handle of the engine to the
“RUN” position.
Speed handle
(3)
Pull the starter handle slowly until resistance is
felt.This is the "compression" point. Return the
handle to its original position.
(4) Push the decompression lever down and
release
.
decompression leve
r
(5) Pull the recoil starter handle hard and fast.
(6)
If the engine fails to start, try again from (3).
2-4.2 Electric starting
Start the engine in accordance with procedures
below:
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 33 34

Comments to this Manuals